Minimum Curing Times for Bonded Windows
For safety reasons, use only non-conductive two-part
adhesive when installing windshield and rear window with the
materials listed below.
The vehicle can o
Overview - Windshield
1 - Windshield
Distance to roof frame: dimension -c- =
2.5 mm
Center the side distance to the A-pillars
2 - Adhesive Bead
Observe the minimum curing t
Overview - Rear Side Window
1 - Rear Side Window
Removing and Installing. Refer to
→ Chapter "Rear Side Window, Removing and Installing".
after installing push in first with the
Safety Precautions
Safety Precautions when Working on High-Voltage System
Danger to life through high-voltage.
The high-voltage system operates through high-voltage.
Electrocution can cause death or very serious personal injury.
- Persons with internal electronic/medical life support
devices
Aerial Cable Repair Set VAS6720
Special tools and workshop equipment
required
Aerial Cable Repair Set -VAS6720-
The Aerial Cable Repair Set -VAS6720- makes it possible to
perform a quality repair on antenna wires RG 174 (blue) and RTK
031 (black). The set contains the insulation removal tools