Coolant Recirculation Pump -V50-, Removing and Installing
Special tools and workshop equipment
required
Hose Clamps - Up To 25 mm -3094-
Hose Clip Pliers -VAS6340-
Removing
- Remove the air filter housing. Refer to
→ Chapter "Air Filter Housing, Removing and Installing".
- Fre
ATF Level, Checking
ATF Level, Checking, 0D3 "Sport Differential"
Caution
This procedure contains mandatory replaceable parts.
Refer to component overview prior to starting procedure.
Mandatory Replacement Parts
Plug - ATF check
Test Requirement
ATF temperature: 10 ºC to 60 ºC (50 t